Product Description

The Diacell® LeverDAC-Mini is strongly constructed.  Pressure is generated by means of a hand wheel and screw acting on disc springs.  These in turn actuate a lever and presser plate mechanism.  The lower presser plate drives a piston on which one of the diamond anvils is mounted.  The opposing anvil is held on a fixed plate.  The Diacell® LeverDAC-Mini has been designed with particular attention to ease of operation.

The numerical aperture (NA) of the Diacell® LeverDAC-Mini is 0.4 which matches well the NA's of most FTIR instruments. Hence no beam condenser is needed.

The Diacell® LeverDAC–Mini is shipped aligned and ready for use, and included are two tubes which allow evaporated liquid nitrogen to be passed around the anvils thus providing cooling usefully at low temperatures suitable for work of a biological nature.

Applications

The Diacell® LeverDAC-Mini is suitable for analytical use, and particularly useful for biological applications. This diamond anvil cell was designed for analytical and forensic applications in which the primary requirement is to be able to spread a small specimen over a wider area so that it may be more readily studied by spectroscopic and other means.  Its particular appeal, especially in the forensic field, lies in the fact that the sample is not adulterated in any way, and is recoverable directly.  Only very small samples are required: they may be loaded and compressed directly. Alternatively, and also for liquid samples, the sample may be held within a thin metal gasket having a central hole of about 0.5 mm diameter.

The Diacell® LeverDAC-Mini is also particularly suitable for biological studies involving proteins, bacteria and foodstuffs.  For applications such as spreading out small flakes of paint, surprisingly high loads are needed.


TECHNICAL SPECIFICATION

Cell Material Stainless Steel AISI 440C
Anvil Support Plate Integrated supports – Tool Steel
Pressure Mechanism Lever Arm Drive
Maximum Range 30 GPa
Temperature Range Around Room Temperature
Top Angle Optical: Conical 52°
Bottom Angle Optical: Conical 52°
Lateral Access N/A
Heating N/A
Cooling Evaporated Liquid Nitrogen
DAC Length / Width 120 mm / 63 mm
DAC Height (at cell) 25 mm
Working Distance to Sample 6 mm
Numerical Aperture 0.44
Interfacing Solution TBC

Maximum pressure is dependent upon the culet size of the anvils.
Almax easyLab is committed to its policy of continuous improvement.
Specifications may change without notice.
easyLab and Diacell are registered trademarks of Almax easyLab Ltd.


PARAMETERS

EXPERIMENTAL
TECHNIQUES
far-IR | Fluorescence | FTIR | Infrared | Mossbauer | Raman
MAX
PRESSURE
1 GPa | 10 GPa | 3.0 GPa | 30 GPa
TEMPERATURE
RANGE
Low Temperatures | Room Temperature